With around 250 locations and 90 serve centers, we are represented in the most important economic regions of the world. The advantages are clear: short paths to our customers, fast response times and a shared language.
Recirculation from the pump discharge through a cyclone separator delivering the clean fluid to a cooler and then to the seal chamber. The solids are delivered to the pump suction line.
A Cyclone separator
B Cooler
C Temperature indicator
D Contaminated liquid IN
E Clean liquid OUT
F Separated liquid OUT
1 From cooler
2 Flush (F)
3 Quench (Q)
4 Drain (D)
5 Seal chamber
Example seal: EagleBurgmann H75VA4-S single pusher mechanical seal.
Key
TI Temperature indicator
1CW-FL, 1CW-FX, 2CW-CW, 2CW-CS, 3CW-FB, 3CW-BB, 3CW-FF
3NC-FB*, 3NC-BB*, 3NC-FF*
* Remark: The configurations listed for each individual piping plan are to be understood as recommendations including possible utilizations which may also be applied.
Follow the direct link to your API 682 4th ed. contact
Download the free EagleBurgmann API piping plan tool and benefit from useful and practical information