SPO (Plan 53B) - Product variants

Designation SPB6000A4 SPB6001A4 SPB6000A4 SPB6001A4
Design code ASME VIII, Div.1 PED 2014/68/EU ASME VIII, Div.1 PED 2014/68/EU
Type of cooler Air
cooler a)
Water
cooler b)
Air
cooler a)
Water
cooler b)
Air
cooler a)
Water
cooler b)
Air
cooler a)
Water
cooler b)
For shaft diameters
≤60 mm (acc. to API 682)
For shaft diameters
>60 mm (acc. to API 682)
Bladder accumulator (liters) 20 20 35 35
Allowable pressure1) 44 bar (638 PSI) 44 bar (638 PSI) 44 bar (638 PSI) 44 bar (638 PSI)
Allowable temperature -
bladder accumulator1)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
Allowable temperature -
system1)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
-20 °C … +90 °C
(-4 °F … +194 °F)
Cooling capacity –
with water cooled heat exchanger (kW)2)
10 10 10 10
Cooling capacity –
with air cooled heat exchanger (kW)2)
2.0 2.0 2.0 2.0
Metal parts 316/316L 316/316L 316/316L 316/316L
Accumulator CrMo steel CrMo steel CrMo steel CrMo steel
Bladder Nitrile Nitrile Nitrile Nitrile

Other versions and connections (flanged, threaded, welded) on request.

1) Design data, permissible working values depend on the actual conditions of service.
2) The cooling performance depends on the available fluids, their temperatures and flow rates. Please contact EagleBurgmann for professionally selecting the correct heat exchanger.

a) WEL6002A4
b) WEF6100A4







For a larger view, please mouseover the image.
SPO with a water cooler
{u'ApplicationOperationalArea': '', u'IDProductItem': '1092', u'IDProductInfo': '2341', u'RecipientPhone': '', u'OperatingLimits': '', u'Note': 'A refilling unit has to be provided.', u'TechnicalData': 'Pressurized barrier system (closed circuit) for use in seal systems with high pressures and/or for hazardous/environmentally harmful processes. The SPO (Plan 53B) range is available with a pressure accumulator, cooler (finned tube, water or air cooler with fan) and a wide range of instruments.<br/>\n<br/>\nCirculation in accordance with API 682 / ISO 21049: <a href="resolveuid/615ac411f94a4f66932ea3c6cd7a39ff" target="_blank">Plan 53B</a>', u'Online': 'true', u'DrawingProduct': 'None', u'Level2ProductGroup_Group': 'None', u'ProductDomain': 'None', u'IDProductItemH': '1090', u'Description': '', u'TorqueTransmission': '', u'InquiryClass': '', u'PageHeader': 'SPO (Plan 53B)', u'MailRecipient': '', u'Level1ProductRange_Range': '', u'DrawingInstallation': 'None', u'Level3ProductSection_Section': '', u'IDInquiryClass': '', u'StructureLevel': 'Group', u'SupplySystem': '', u'SeatAlternative': '', u'Language': 'en-US', u'MediaResistance': '', u'DescriptionHeader': '', u'RecipientName': '', u'Position': '1', u'ApplicationBranch': '<ul class="SGBulletList">\n<li>Petrochemical industry</li>\n<li>Chemical industry</li>\n<li>Oil and gas industry</li>\n<li>Refining technology</li>\n</ul>', u'DimensionHeader': '', u'Dimension': '', u'UID': 'd8ae93b9ad9a61f0d95e1954e6e4ee86', u'TechnicalDiagram': '', u'Features': 'The SPO is designed to perform the following functions of a barrier system:<br/>\n<ul class="SGBulletList">\n<li>to pressurize the barrier chamber</li>\n<li>leakage compensation</li>\n<li>to cool the seal</li>\n</ul>\n<br/><br/>\nPressurization (> process pressure) prevents the process medium from getting into the barrier circuit or the atmosphere. Pressurization is supplied by a pressure accumulator which is pre-loaded with nitrogen. Circulation in the barrier circuit takes place by the thermosiphon principle or by forced circulation, e.g. with a pumping screw.<br/>', u'Certification': '<ul class="SGBulletList">\n<li>PED 2014/68/EU (Design and production in accordance with EU Pressure Equipment Directive)</li>\n<li>ASME VIII, Div. 1 (Design, calculation and production)</li>\n</ul>', u'DescriptionText': '', u'SealCodes': '', u'MaterialCombination': '', u'ProductVariant': 'None', u'ProductName': 'SPO Plan 53B', u'ArticleNumber': '', u'SupplyForm': '', u'IDSealDrawing': '', u'GenerateMeasurement': '', u'DescriptionList': '<ul class="SGBulletList">\n<li>Pressurization is by means of a pre-loaded bladder accumulator</li>\n<li>The nitrogen is separated from the barrier medium by membranes in the accumulator: nitrogen cannot get into the barrier medium or process medium</li>\n<li>Barrier pressure is created without any need for connection to a nitrogen supply</li>\n<li>Available with finned tube, water or air coolers with fan</li>\n<li>Modular system: combination with a wide range of system components/instruments possible</li>\n</ul>', u'ApplicationMedia': ''}